On Thursday 05 February 2004 08:54 pm, Nate Lawson wrote: > Actually, after looking at Peter's MADT, it appears it does have an > override from 9 to 20 with the polarity "conforming" and level-triggered. > I assume that conforming means low for his system. Does he have conforming polarity or active-hi? If it's conforming then I might be able to work around this. I thought it was acthive-hi though. (Other broken boards use active-hi / level but need active-lo / level to work.) -- John Baldwin <jhb_at_FreeBSD.org> <>< http://www.FreeBSD.org/~jhb/ "Power Users Use the Power to Serve" = http://www.FreeBSD.orgReceived on Fri Feb 06 2004 - 10:25:22 UTC
This archive was generated by hypermail 2.4.0 : Wed May 19 2021 - 11:37:42 UTC