On 2004-06-10T14:28:48+1000, Alastair G. Hogge wrote: > Thought about this. But I don't think it is the case. I've had the 2 HD for > sometime now, and I they used to 24/7. I have 3 fans running in my tower > case. > > I've just re-built world again recently and I'm still getting problems. > > I need to get that other machine going. I am using an on-board Promise controller, and had similar problems when first setting up this server. # pciconf -lv | grep -B1 -A3 Promise atapci0_at_pci2:2:0: class=0x010485 card=0x1275105a chip=0x5275105a rev=0x01 hdr=0x00 vendor = 'Promise Technology Inc' device = 'PDC20276 Ultra133 TX2/FastTrak TX Lite EIDE Controller' class = mass storage subclass = RAID What I discovered was that my cables were too long. I had purchased those round cables in order to reduce air flow restrictions in the case, but at the time, I could only get 36" cables. After quite a few lost mirrors, I found out that those cables _should_ be a maximum of 18" long. I replaced the 36" cables with 18" cables and haven't had a problem since. I don't know if this will help you, but it certainly fixed the problems that I was having. Good luck. -- Mike perl -e 'print unpack("u","88V]N=&%C=\"!I;F9O(&EN(&AE861E<G,*");'
This archive was generated by hypermail 2.4.0 : Wed May 19 2021 - 11:37:56 UTC