ShouYan Mao wrote: > > So, would you try it with PCI-E Gigabit card? I would if I had a PCI-E system and suitable PCI-E Gigabit cards. Feel free to send me a test system. -- Andre > Best Regards. > Shouyan > > ------------------------------------------------------- > I'm not the best, but I try to do better. > ------------------------------------------------------- > > -----Original Message----- > From: owner-freebsd-net_at_freebsd.org [mailto:owner-freebsd-net_at_freebsd.org] On Behalf Of Andre Oppermann > Sent: 2005Äê12ÔÂ23ÈÕ 2:17 > To: freebsd-current_at_freebsd.org > Cc: freebsd-net_at_freebsd.org > Subject: Network performance measurements of -current > > As part my funded TCP/IP optimization work I'm doing lots of measurements > and profiling with an Agilent N2X network tester and calibrated traffic > generator. > > The following data shall serve as baseline of the current performance we > get out of FreeBSD 7-current. More to come tomorrow though. > > OS: FreeBSD 7-current as of 20051222-1600 UTC > KERNEL: Generic kernel, minus WITNESS and INVARIANTS, plus HWPMC, HZ=1000 > HARDWARE: Dual Opteron 852 2.6Ghz, Tyan S2882 Mobo with AMD-8131 PCI-X tunnel > HARDWARE: dual Broadcom Gigabit BMC5704C PCI-X-133 ("bge") > HARDWARE: dual Intel Gigabit 82546EB PCI-X-133 ("em") > > Uniprocessor kernel > > bge: > normal forwarding bge0->bge1: _at_64/326kpps/166us/402kpps(30%Loss)/194us > normal forwarding bge0->bge1: _at_1500/81kpps/520us > normal forwarding bge0->disc0: _at_64/1205kpps > IP fastforwarding bge0->bge1: _at_64/565kpps/192us/575kpps(60%Loss)/1090us > IP fastforwarding bge0->bge1: _at_1500/81kpps/730us > IP fastforwarding bge0->disc0: _at_64/1160kpps > net.isr.direct=1 bge0->bge1: _at_64/476kpps/211us/487kpps(68%Loss)/1284us > net.isr.direct=1 bge0->bge1: _at_1500/81kpps/760us > net.isr.direct=1 bge0->disc0: _at_64/1250kpps > polling (*) bge0->bge1: > _at_64/420kpps(9%Loss)/1385us/416kpps(72%Loss)/1600us > polling (*) bge0->bge1: _at_1500/71kpps(9%Loss)/850us > polling (*) bge0->disc0: _at_64/697kpps > > Comments: Under full load the normal processing breaks completely down > while with IP fastforwarding it levels off but continues to forward. > Strangely with polling it has 9% loss at all loads (even at 1% wirespeed). > May be related to HZ=1000. > > em: > normal forwarding em0->em1: _at_64/372kpps/112us/396kpps(11%Loss)/131us > normal forwarding em0->em1: _at_1500/81kpps/170us > normal forwarding em0->disc0: _at_64/1130kpps > IP fastforwarding em0->em1: _at_64/565kpps/45us/585kpps(4%Loss)/1600us > IP fastforwarding em0->em1: _at_1500/81kpps/135us > IP fastforwarding em0->disc0: _at_64/1116kpps > net.isr.direct=1 em0->em1: later > net.isr.direct=1 em0->disc0: later > polling (*) em0->em1: later > polling (*) em0->disc0: later > > (*) max_burst=1000, user_frac=0, each_burst=30 > > Sponsored by: TCP/IP Optimization Fundraise 2005 > > -- > Andre > _______________________________________________ > freebsd-net_at_freebsd.org mailing list > http://lists.freebsd.org/mailman/listinfo/freebsd-net > To unsubscribe, send any mail to "freebsd-net-unsubscribe_at_freebsd.org"Received on Fri Dec 23 2005 - 08:32:18 UTC
This archive was generated by hypermail 2.4.0 : Wed May 19 2021 - 11:38:49 UTC