Well, based upon the serial number they aren't the same disk then. On Fri, 9 Mar 2007, Ivan Voras wrote: > Hmm, the script is silent. > > Here's output from some camcontrols commands I've picked from the script: > > # camcontrol devl > <IBM-ESXS MAY2073RC T107> at scbus0 target 0 lun 0 (pass0,da0) > <IBM 1724-100 FAStT 0542> at scbus1 target 0 lun 0 (pass1,da1) > <IBM 1724-100 FAStT 0542> at scbus1 target 1 lun 0 (pass2,da2) > quad:~/bin# camcontrol inquiry da1 > pass1: <IBM 1724-100 FAStT 0542> Fixed Direct Access SCSI-3 device > pass1: Serial Number 1T60567771 > pass1: 100.000MB/s transfers , Tagged Queueing Enabled > quad:~/bin# camcontrol inquiry da2 > pass2: <IBM 1724-100 FAStT 0542> Fixed Direct Access SCSI-3 device > pass2: Serial Number 1T60567625 > pass2: 100.000MB/s transfers , Tagged Queueing Enabled > > But they are the same device - if I write something on one of them, I > can read it from the other. > >Received on Fri Mar 09 2007 - 22:33:47 UTC
This archive was generated by hypermail 2.4.0 : Wed May 19 2021 - 11:39:06 UTC