Re: panic: in pf_reassemble() ?

From: Ian FREISLICH <ianf_at_clue.co.za>
Date: Fri, 21 Aug 2009 21:05:17 +0200
Max Laier wrote:
> On Friday 21 August 2009 17:01:14 Ian Freislich wrote:
> > 0xffffff 81ccae4710 ---
> > pf_reassemble() at pf_reassemble+0xb1
> > pf_normalize_ip() at pf_normalize_ip+0x694
> 
> Can you get me line numbers for these two?

How?

> > pf_test() at pf_test+0x78e
> > pf_check_in() at pf_check_in+0x39
> > pfil_run_hooks() at pfil_run_hooks+0x9c
> > ip_fastforward() at ip_fastforward+0x319
> 
> Does switching fast forward off change the situation - not that it
> should, but it might help with finding the culprit.

I'll test and let you know.  I'm also running Watson's:

net.isr.maxthreads=8
net.isr.direct=0

But, these didn't seem to make a difference either.

> > ether_demux() at ether_demux+0x131
> > ether_input() at ether_input+0x1e0
> > ether_demux() at ether_demux+0x6f
> > ether_input() at ether_input+0x1e0
> > bce_intr() at bce_intr+0x398
> > intr_event_execute_handlers() at intr_event_execute_handlers+0x100
> > ithread_loop() at ithread_loop+0x8e
> > fork_exit() at fork_exit+0x117
> > fork_trampoline() at fork_trampoline+0xe
> > --- trap 0, rip =3D 0, rsp =3D 0xffffff81ccae4d30, rbp =3D 0 ---
> >
> > I can setup remote GDB and set this panic off again if there's
> > something specific someone would like me to look at.
>
> From a very first glance this could be a byte order mismatch in ip_len
> or the like, so if you could take a look at the ip header in the
> involved mbufs.  Anything that looks like swapped bytes.  Are you
> using jumbo frames?

We're not using jumbo frames.  It'll take me a while to setup a
test-bed.  This happened on my live routers.  It panicked the first
one, the carp failover and it panicked the second one.  I'm away
for a week now, so if I don't manage to get this done before we
leave, it'll be the first thing I do when I get back.

It's easily reproduceable:

Mine's a 16 core amd64 with 4x bce(4) interfaces in a lagg(4) and
vlans using the lagg as the parent (but I doubt that's involved).
At the time there were about 180000 states + 40000 NAT states on
the firewall.  Limits are as high as they are because we've been
up to about 430000 states in the past.

pf.conf:
# Options
# ~~~~~~~
set timeout { \
        adaptive.start  480000, \
        adaptive.end    960000 \
        }
set state-policy if-bound
set optimization normal
set ruleset-optimization basic
set limit states 800000
set limit frags 40000
set limit src-nodes 150000
# Normalization
# ~~~~~~~~~~~~~
scrub on tun0 all fragment reassemble
scrub on vlan2 all fragment reassemble
scrub on vlan3 all fragment reassemble
scrub on vlan4 all fragment reassemble
scrub on vlan5 all fragment reassemble
scrub on vlan7 all fragment reassemble
scrub on vlan8 all fragment reassemble
scrub on vlan9 all fragment reassemble
scrub on vlan14 all fragment reassemble
scrub on vlan15 all fragment reassemble
scrub on vlan20 all fragment reassemble
scrub on vlan21 all fragment reassemble
scrub on vlan22 all fragment reassemble
scrub on vlan23 all fragment reassemble
scrub on vlan25 all fragment reassemble
scrub on vlan26 all fragment reassemble

# Queueing
# ~~~~~~~~
altq on lagg0 cbq bandwidth 8Gb queue { vlan2_m_in, vlan2_m_out, default }
queue vlan2_m_in       bandwidth 100Mb { vlan2_in, vlan15_in }
queue vlan2_m_out      bandwidth 100Mb { vlan2_out, vlan15_out }
queue vlan2_in         bandwidth 80Mb borrow
queue vlan2_out        bandwidth 80Mb borrow
queue vlan15_in        bandwidth 20Mb
queue vlan15_out       bandwidth 20Mb
queue default          bandwidth 7176Mb cbq(default)

Then use netperf from a machine on one vlan to a machine on another vlan:

netperf -tUDP_STREAM -i2 -H othermachine

It takes about 3 seconds to panic.

Ian

--
Ian Freislich
Received on Fri Aug 21 2009 - 17:05:20 UTC