on 11/09/2010 21:30 Nate Lawson said the following: > I think the issue is that C2 is not available for some reason and thus > C3 can't be used either. The way to tell is to use acpidump and look for > the CPU objects' _CST fields. >From reading of the code, C3 should be used in this case even if C2 is not available. But I think that it might get removed for a different reason: PM2_CNT_BLK length seems to be zero. With ACPI_DB_INFO enabled there should be "no BM control" message in the log. -- Andriy GaponReceived on Sun Sep 12 2010 - 06:01:21 UTC