LOR in r295717M

From: Robison, Dave <david.robison_at_fisglobal.com>
Date: Mon, 14 Mar 2016 15:16:06 -0700
Hope this is the right place to take this. I can provide more info as requested.



lock order reversal:
 1st 0xfffffe03e1823700 bufwait (bufwait) _at_ /usr/src/sys/kern/vfs_bio.c:3488
 2nd 0xfffff80005286200 dirhash (dirhash) _at_ /usr/src/sys/ufs/ufs/ufs_dirhash.c:281
stack backtrace:
#0 0xffffffff80a7fc60 at witness_debugger+0x70
#1 0xffffffff80a7fb61 at witness_checkorder+0xe71
#2 0xffffffff80a2d152 at _sx_xlock+0x72
#3 0xffffffff80cc562d at ufsdirhash_add+0x3d
#4 0xffffffff80cc84df at ufs_direnter+0x62f
#5 0xffffffff80cd1843 at ufs_makeinode+0x5f3
#6 0xffffffff80ccd3ed at ufs_create+0x2d
#7 0xffffffff80fbb561 at VOP_CREATE_APV+0xf1
#8 0xffffffff80ae6a18 at vn_open_cred+0x2f8
#9 0xffffffff80adfd9c at kern_openat+0x25c
#10 0xffffffff80e6f15b at amd64_syscall+0x2db
#11 0xffffffff80e4ed5b at Xfast_syscall+0xfb


lock order reversal:
 1st 0xfffff80021da2d50 ufs (ufs) _at_ /usr/src/sys/kern/vfs_syscalls.c:3400
 2nd 0xfffffe03e1823700 bufwait (bufwait) _at_ /usr/src/sys/ufs/ffs/ffs_vnops.c:263
 3rd 0xfffff80025d1ed50 ufs (ufs) _at_ /usr/src/sys/kern/vfs_subr.c:2476
stack backtrace:
#0 0xffffffff80a7fc60 at witness_debugger+0x70
#1 0xffffffff80a7fb61 at witness_checkorder+0xe71
#2 0xffffffff809ff22b at __lockmgr_args+0xd3b
#3 0xffffffff80cc06b6 at ffs_lock+0xa6
#4 0xffffffff80fbdb00 at VOP_LOCK1_APV+0x100
#5 0xffffffff80ae71ba at _vn_lock+0x9a
#6 0xffffffff80ad7783 at vget+0x63
#7 0xffffffff80aca08c at vfs_hash_get+0xcc
#8 0xffffffff80cbbda0 at ffs_vgetf+0x40
#9 0xffffffff80cb3731 at softdep_sync_buf+0xad1
#10 0xffffffff80cc1296 at ffs_syncvnode+0x256
#11 0xffffffff80cc0550 at ffs_fsync+0x20
#12 0xffffffff80fbcbc7 at VOP_FSYNC_APV+0xf7
#13 0xffffffff80ae3e30 at sys_fsync+0x170
#14 0xffffffff80e6f15b at amd64_syscall+0x2db
#15 0xffffffff80e4ed5b at Xfast_syscall+0xfb


dmesg info:

daver_at_hvm1a:~ % cat /var/run/dmesg.boot
Copyright (c) 1992-2016 The FreeBSD Project.
Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994
        The Regents of the University of California. All rights reserved.
FreeBSD is a registered trademark of The FreeBSD Foundation.
FreeBSD 11.0-CURRENT #0 r295717M: Mon Feb 22 12:24:00 PST 2016
    root_at_hvm1a.dev.vicor.com:/usr/obj/usr/src/sys/GENERIC amd64
FreeBSD clang version 3.7.1 (tags/RELEASE_371/final 255217) 20151225
WARNING: WITNESS option enabled, expect reduced performance.
VT(vga): resolution 640x480
CPU: Intel(R) Xeon(R) CPU            5150  _at_ 2.66GHz (2660.06-MHz K8-class CPU)
  Origin="GenuineIntel"  Id=0x6f6  Family=0x6  Model=0xf  Stepping=6
  Features=0xbfebfbff<FPU,VME,DE,PSE,TSC,MSR,PAE,MCE,CX8,APIC,SEP,MTRR,PGE,MCA,CMOV,PAT,PSE36,CLFLUSH,DTS,ACPI,MMX,FXSR,SSE,SSE2,SS,HTT,TM,PBE>
  Features2=0x4e3bd<SSE3,DTES64,MON,DS_CPL,VMX,EST,TM2,SSSE3,CX16,xTPR,PDCM,DCA>
  AMD Features=0x20100800<SYSCALL,NX,LM>
  AMD Features2=0x1<LAHF>
  VT-x: (disabled in BIOS) HLT,PAUSE
  TSC: P-state invariant, performance statistics
real memory  = 17179869184 (16384 MB)
avail memory = 16553672704 (15786 MB)
Event timer "LAPIC" quality 400
ACPI APIC Table: <INTEL  S5000PAL>
FreeBSD/SMP: Multiprocessor System Detected: 2 CPUs
FreeBSD/SMP: 1 package(s) x 2 core(s)
 cpu0 (BSP): APIC ID:  0
 cpu1 (AP): APIC ID:  1
random: unblocking device.
ioapic0 <Version 2.0> irqs 0-23 on motherboard
ioapic1 <Version 2.0> irqs 24-47 on motherboard
random: entropy device external interface
kbd1 at kbdmux0
netmap: loaded module
module_register_init: MOD_LOAD (vesa, 0xffffffff80ee2ef0, 0) error 19
vtvga0: <VT VGA driver> on motherboard
cryptosoft0: <software crypto> on motherboard
acpi0: <INTEL S5000PAL> on motherboard
acpi0: Power Button (fixed)
cpu0: <ACPI CPU> on acpi0
cpu1: <ACPI CPU> on acpi0
atrtc0: <AT realtime clock> port 0x70-0x71,0x74-0x77 irq 8 on acpi0
Event timer "RTC" frequency 32768 Hz quality 0
attimer0: <AT timer> port 0x40-0x43,0x50-0x53 irq 0 on acpi0
Timecounter "i8254" frequency 1193182 Hz quality 0
Event timer "i8254" frequency 1193182 Hz quality 100
hpet0: <High Precision Event Timer> iomem 0xfed00000-0xfed003ff on acpi0
Timecounter "HPET" frequency 14318180 Hz quality 950
Event timer "HPET" frequency 14318180 Hz quality 450
Event timer "HPET1" frequency 14318180 Hz quality 440
Event timer "HPET2" frequency 14318180 Hz quality 440
Timecounter "ACPI-fast" frequency 3579545 Hz quality 900
acpi_timer0: <24-bit timer at 3.579545MHz> port 0x408-0x40b on acpi0
acpi_button0: <Power Button> on acpi0
pcib0: <ACPI Host-PCI bridge> port 0xcf8-0xcff on acpi0
pci0: <ACPI PCI bus> on pcib0
pcib1: <ACPI PCI-PCI bridge> at device 2.0 on pci0
pci1: <ACPI PCI bus> on pcib1
pcib2: <ACPI PCI-PCI bridge> irq 16 at device 0.0 on pci1
pci2: <ACPI PCI bus> on pcib2
pcib3: <ACPI PCI-PCI bridge> irq 16 at device 0.0 on pci2
pci3: <ACPI PCI bus> on pcib3
pcib4: <ACPI PCI-PCI bridge> at device 0.0 on pci3
pci4: <ACPI PCI bus> on pcib4
mfi0: <LSI MegaSAS 1064R> mem 0xb8b00000-0xb8b0ffff,0xb8900000-0xb891ffff irq 18 at device 14.0 on pci4
mfi0: Using MSI
mfi0: Megaraid SAS driver Ver 4.23 
mfi0: FW MaxCmds = 1008, limiting to 128
pcib5: <PCI-PCI bridge> at device 0.2 on pci3
pci5: <PCI bus> on pcib5
pcib6: <ACPI PCI-PCI bridge> irq 16 at device 1.0 on pci2
pci6: <ACPI PCI bus> on pcib6
pcib7: <ACPI PCI-PCI bridge> irq 16 at device 2.0 on pci2
pci7: <ACPI PCI bus> on pcib7
em0: <Intel(R) PRO/1000 Network Connection 7.6.1-k> port 0x3020-0x303f mem 0xb8820000-0xb883ffff,0xb8400000-0xb87fffff irq 18 at device 0.0 on pci7
em0: Using an MSI interrupt
em0: Ethernet address: 00:15:17:db:55:98
em0: netmap queues/slots: TX 1/1024, RX 1/1024
em1: <Intel(R) PRO/1000 Network Connection 7.6.1-k> port 0x3000-0x301f mem 0xb8800000-0xb881ffff,0xb8000000-0xb83fffff irq 19 at device 0.1 on pci7
em1: Using an MSI interrupt
em1: Ethernet address: 00:15:17:db:55:99
em1: netmap queues/slots: TX 1/1024, RX 1/1024
pcib8: <ACPI PCI-PCI bridge> at device 0.3 on pci1
pci8: <ACPI PCI bus> on pcib8
pcib9: <PCI-PCI bridge> at device 3.0 on pci0
pci9: <PCI bus> on pcib9
pcib10: <ACPI PCI-PCI bridge> at device 4.0 on pci0
pci10: <ACPI PCI bus> on pcib10
pcib11: <ACPI PCI-PCI bridge> at device 5.0 on pci0
pci11: <ACPI PCI bus> on pcib11
mps0: <Avago Technologies (LSI) SAS2308> port 0x2000-0x20ff mem 0xb8d40000-0xb8d4ffff,0xb8d00000-0xb8d3ffff irq 18 at device 0.0 on pci11
mps0: Firmware: 20.00.02.00, Driver: 20.00.00.00-fbsd
mps0: IOCCapabilities: 5285c<ScsiTaskFull,DiagTrace,SnapBuf,EEDP,TransRetry,EventReplay,HostDisc>
pcib12: <ACPI PCI-PCI bridge> at device 6.0 on pci0
pci12: <ACPI PCI bus> on pcib12
pcib13: <ACPI PCI-PCI bridge> at device 7.0 on pci0
pci13: <ACPI PCI bus> on pcib13
uhci0: <Intel 631XESB/632XESB/3100 USB controller USB-1> port 0x4080-0x409f irq 23 at device 29.0 on pci0
uhci0: LegSup = 0x2f00
usbus0 on uhci0
uhci1: <Intel 631XESB/632XESB/3100 USB controller USB-2> port 0x4060-0x407f irq 22 at device 29.1 on pci0
uhci1: LegSup = 0x2f00
usbus1 on uhci1
uhci2: <Intel 631XESB/632XESB/3100 USB controller USB-3> port 0x4040-0x405f irq 23 at device 29.2 on pci0
uhci2: LegSup = 0x2f00
usbus2 on uhci2
uhci3: <Intel 631XESB/632XESB/3100 USB controller USB-4> port 0x4020-0x403f irq 22 at device 29.3 on pci0
uhci3: LegSup = 0x2f00
usbus3 on uhci3
ehci0: <Intel 63XXESB USB 2.0 controller> mem 0xb8e00400-0xb8e007ff irq 23 at device 29.7 on pci0
usbus4: EHCI version 1.0
usbus4 on ehci0
pcib14: <ACPI PCI-PCI bridge> at device 30.0 on pci0
pci14: <ACPI PCI bus> on pcib14
vgapci0: <VGA-compatible display> port 0x1000-0x10ff mem 0xb0000000-0xb7ffffff,0xb8c00000-0xb8c0ffff irq 17 at device 12.0 on pci14
vgapci0: Boot video device
isab0: <PCI-ISA bridge> at device 31.0 on pci0
isa0: <ISA bus> on isab0
atapci0: <Intel 63XXESB2 UDMA100 controller> port 0x1f0-0x1f7,0x3f6,0x170-0x177,0x376,0x40b0-0x40bf irq 20 at device 31.1 on pci0
ata0: <ATA channel> at channel 0 on atapci0
atapci1: <Intel 63XXESB2 SATA300 controller> port 0x40c8-0x40cf,0x40e4-0x40e7,0x40c0-0x40c7,0x40e0-0x40e3,0x40a0-0x40af mem 0xb8e00000-0xb8e003ff irq 20 at device 31.2 on pci0
ata2: <ATA channel> at channel 0 on atapci1
ata3: <ATA channel> at channel 1 on atapci1
uart0: <16550 or compatible> port 0x3f8-0x3ff irq 4 flags 0x10 on acpi0
uart1: <16550 or compatible> port 0x2f8-0x2ff irq 3 on acpi0
atkbdc0: <Keyboard controller (i8042)> port 0x60,0x64 irq 1 on acpi0
atkbd0: <AT Keyboard> irq 1 on atkbdc0
kbd0 at atkbd0
atkbd0: [GIANT-LOCKED]
orm0: <ISA Option ROMs> at iomem 0xc0000-0xc8fff,0xce800-0xcf7ff,0xcf800-0xd07ff,0xd0800-0xd67ff on isa0
ppc0: cannot reserve I/O port range
est0: <Enhanced SpeedStep Frequency Control> on cpu0
est1: <Enhanced SpeedStep Frequency Control> on cpu1
mfi0: 19700 (509494462s/0x0020/info) - Shutdown command received from host
mfi0: 19701 (boot + 0s/0x0020/info) - Firmware initialization started (PCI ID 0411/1000/3501/8086)
mfi0: 19702 (boot + 0s/0x0020/info) - Firmware version 1.12.280-0826
mfi0: 19703 (boot + 23s/0x0008/info) - Battery temperature is normal
mfi0: 19704 (boot + 23s/0x0008/info) - Battery Present
mfi0: 19705 (boot + 24s/0x0020/info) - Board Revision 
mfi0: 19706 (boot + 53s/0x0004/info) - Enclosure (SES) discovered on PD 07(c None/p1)
mfi0: 19707 (boot + 53s/0x0002/info) - Inserted: Encl PD 07
mfi0: MFI_DCMD_PD_LIST_QUERY failed 2
mfi0: 19708 (boot + 53s/0x0002/info) - Inserted: PD 07(c None/p1) Info: enclPd=07, scsiType=d, portMap=09, sasAddr=5000007000580000,0000000000000000
mfi0: 19709 (boot + 53s/0x0002/info) - Inserted: PD 1c(e0x07/s0)
mfi0: MFI_DCMD_PD_LIST_QUERY failed 2
mfi0: 19710 (boot + 53s/0x0002/info) - Inserted: PD 1c(e0x07/s0) Info: enclPd=07, scsiType=0, portMap=00, sasAddr=83945143a499a876,0000000000000000
mfi0: 19711 (boot + 53s/0x0002/info) - Inserted: PD 1d(e0x07/s1)
mfi0: MFI_DCMD_PD_LIST_QUERY failed 2
mfi0: 19712 (boot + 53s/0x0002/info) - Inserted: PD 1d(e0x07/s1) Info: enclPd=07, scsiType=0, portMap=01, sasAddr=839544489e9aad93,0000000000000000
mfi0: 19713 (boot + 53s/0x0002/info) - Inserted: PD 1e(e0x07/s2)
mfi0: MFI_DCMD_PD_LIST_QUERY failed 2
mfi0: 19714 (boot + 53s/0x0002/info) - Inserted: PD 1e(e0x07/s2) Info: enclPd=07, scsiType=0, portMap=02, sasAddr=83985540c098cb92,0000000000000000
mfi0: 19715 (boot + 53s/0x0002/info) - Inserted: PD 1f(e0x07/s3)
mfi0: MFI_DCMD_PD_LIST_QUERY failed 2
mfi0: 19716 (boot + 53s/0x0002/info) - Inserted: PD 1f(e0x07/s3) Info: enclPd=07, scsiType=0, portMap=03, sasAddr=8394473ac3acd095,0000000000000000
mfi0: 19717 (509496114s/0x0020/info) - Time established as 02/22/16 22:41:54; (55 seconds since power on)
usbus0: 12Mbps Full Speed USB v1.0
Timecounters tick every 1.000 msec
IPsec: Initialized Security Association Processing.
usbus1: 12Mbps Full Speed USB v1.0
usbus2: 12Mbps Full Speed USB v1.0
ugen0.1: <Intel> at usbus0
ugen1.1: <Intel> at usbus1
uhub0: <Intel UHCI root HUB, class 9/0, rev 1.00/1.00, addr 1> on usbus0
uhub1: <Intel UHCI root HUB, class 9/0, rev 1.00/1.00, addr 1> on usbus1
ugen2.1: <Intel> at usbus2
uhub2: <Intel UHCI root HUB, class 9/0, rev 1.00/1.00, addr 1> on usbus2
usbus3: 12Mbps Full Speed USB v1.0
usbus4: 480Mbps High Speed USB v2.0
ugen3.1: <Intel> at usbus3
ugen4.1: <Intel> at usbus4
uhub3: <Intel UHCI root HUB, class 9/0, rev 1.00/1.00, addr 1> on usbus3
uhub4: <Intel EHCI root HUB, class 9/0, rev 2.00/1.00, addr 1> on usbus4
mfid0 on mfi0
mfid0: 952720MB (1951170560 sectors) RAID volume (no label) is optimal
uhub0: 2 ports with 2 removable, self powered
uhub1: 2 ports with 2 removable, self powered
uhub2: 2 ports with 2 removable, self powered
mfid1 on mfi0
mfid1: 952720MB (1951170560 sectors) RAID volume (no label) is optimal
mps0: SAS Address for SATA device = 83ae5139c8babb8a
uhub3: 2 ports with 2 removable, self powered
mps0: SAS Address for SATA device = 83ac5340bec1a876
mps0: SAS Address for SATA device = 83984f3cc698c081
mps0: SAS Address for SATA device = 83b43946b6a1cc77
mps0: SAS Address for SATA device = 83984b3ab4b2cd83
mps0: SAS Address for SATA device = 839a5843b3baaf75
mps0: SAS Address for SATA device = 839a4733c7add186
mps0: SAS Address for SATA device = 83a95744a5b4c696
mps0: SAS Address for SATA device = 7e9735279fa59487
mps0: SAS Address for SATA device = 7e973622a2a7958c
mps0: SAS Address from SATA device = 83ae5139c8babb8a
mps0: SAS Address from SATA device = 83ac5340bec1a876
mps0: SAS Address from SATA device = 83984f3cc698c081
mps0: SAS Address from SATA device = 83b43946b6a1cc77
mps0: SAS Address from SATA device = 83984b3ab4b2cd83
mps0: SAS Address from SATA device = 839a5843b3baaf75
mps0: SAS Address from SATA device = 839a4733c7add186
mps0: SAS Address from SATA device = 83a95744a5b4c696
mps0: SAS Address from SATA device = 7e9735279fa59487
mps0: SAS Address from SATA device = 7e973622a2a7958c
mps0: SAS Address for SATA device = 7e9737209fa99788
mps0: SAS Address for SATA device = 7e973321a7ad958c
mps0: SAS Address from SATA device = 7e9737209fa99788
mps0: SAS Address from SATA device = 7e973321a7ad958c
ses0 at mps0 bus 0 scbus0 target 20 lun 0
ses0: <LSI SAS2X28 0e12> Fixed Enclosure Services SPC-3 SCSI device
ses0: Serial Number 
ses0: 600.000MB/s transfers
ses0: Command Queueing enabled
ses0: SCSI-3 ENC Device
ses1 at mps0 bus 0 scbus0 target 21 lun 0
ses1: <LSI SAS2X28 0e12> Fixed Enclosure Services SPC-3 SCSI device
ses1: Serial Number 
ses1: 600.000MB/s transfers
ses1: Command Queueing enabled
ses1: SCSI-3 ENC Device
da0 at mps0 bus 0 scbus0 target 8 lun 0
da0: <ATA WDC WD1003FZEX-0 1A01> Fixed Direct Access SPC-4 SCSI device
da0: Serial Number      WD-WCC3FJNKZRCJ
da0: 600.000MB/s transfers
da0: Command Queueing enabled
da0: 953869MB (1953525168 512 byte sectors)
da1 at mps0 bus 0 scbus0 target 9 lun 0
da1: <ATA WDC WD1003FZEX-0 1A01> Fixed Direct Access SPC-4 SCSI device
da1: Serial Number      WD-WCC3FHPRPY06
da1: 600.000MB/s transfers
da1: Command Queueing enabled
da1: 953869MB (1953525168 512 byte sectors)
da2 at mps0 bus 0 scbus0 target 10 lun 0
da2: <ATA WDC WD1003FZEX-0 1A01> Fixed Direct Access SPC-4 SCSI device
da2: Serial Number      WD-WCC3F4LNX0HA
da2: 600.000MB/s transfers
da2: Command Queueing enabled
da2: 953869MB (1953525168 512 byte sectors)
da3 at mps0 bus 0 scbus0 target 11 lun 0
da3: <ATA WDC WD1003FZEX-0 1A01> Fixed Direct Access SPC-4 SCSI device
da3: Serial Number      WD-WCC3FP6XH9T7
da3: 600.000MB/s transfers
da3: Command Queueing enabled
da3: 953869MB (1953525168 512 byte sectors)
da4 at mps0 bus 0 scbus0 target 12 lun 0
da4: <ATA WDC WD1003FZEX-0 1A01> Fixed Direct Access SPC-4 SCSI device
da4: Serial Number      WD-WCC3F4HLFJUC
da4: 600.000MB/s transfers
da4: Command Queueing enabled
da4: 953869MB (1953525168 512 byte sectors)
da5 at mps0 bus 0 scbus0 target 13 lun 0
da5: <ATA WDC WD1003FZEX-0 1A01> Fixed Direct Access SPC-4 SCSI device
da5: Serial Number      WD-WCC3F6UUER75
da5: 600.000MB/s transfers
da5: Command Queueing enabled
da5: 953869MB (1953525168 512 byte sectors)
da6 at mps0 bus 0 scbus0 target 14 lun 0
da6: <ATA WDC WD1003FZEX-0 1A01> Fixed Direct Access SPC-4 SCSI device
da6: Serial Number      WD-WCC3F6DEYEYF
da6: 600.000MB/s transfers
da6: Command Queueing enabled
da6: 953869MB (1953525168 512 byte sectors)
da7 at mps0 bus 0 scbus0 target 15 lun 0
da7: <ATA WDC WD1003FZEX-0 1A01> Fixed Direct Access SPC-4 SCSI device
da7: Serial Number      WD-WCC3FETV7LNV
da7: 600.000MB/s transfers
da7: Command Queueing enabled
da7: 953869MB (1953525168 512 byte sectors)
da9 at mps0 bus 0 scbus0 target 17 lun 0
da9: <ATA WDC WD1002FAEX-0 1D05> Fixed Direct Access SPC-4 SCSI device
da9: Serial Number      WD-WCATRC344375
da9: 600.000MB/s transfers
da9: Command Queueing enabled
da9: 953869MB (1953525168 512 byte sectors)
da8 at mps0 bus 0 scbus0 target 16 lun 0
ses0: da0,pass0: Element descriptor: 'Slot 01'
da8: <ATA WDC WD1002FAEX-0 1D05> Fixed Direct Access SPC-4 SCSI device
ses0: da0,pass0: SAS Device Slot Element: 1 Phys at Slot 0
da8: Serial Number      WD-WCATRC291160
ses0:  phy 0: SATA device
da8: 600.000MB/s transfersses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a2c

da8: Command Queueing enabled
da8: 953869MB (1953525168 512 byte sectors)
da10 at mps0 bus 0 scbus0 target 18 lun 0
da10: <ATA WDC WD1002FAEX-0 1D05> Fixed Direct Access SPC-4 SCSI device
da10: Serial Number      WD-WCATRC421591
da10: 600.000MB/s transfers
da10: Command Queueing enabled
da10: 953869MB (1953525168 512 byte sectors)
da11 at mps0 bus 0 scbus0 target 19 lun 0
da11: <ATA WDC WD1002FAEX-0 1D05> Fixed Direct Access SPC-4 SCSI device
da11: Serial Number      WD-WCATRC039975
da11: 600.000MB/s transfers
da11: Command Queueing enabled
da11: 953869MB (1953525168 512 byte sectors)
ses0: da1,pass1: Element descriptor: 'Slot 02'
ses0: da1,pass1: SAS Device Slot Element: 1 Phys at Slot 1
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a2d
ses0: da2,pass2: Element descriptor: 'Slot 03'
ses0: da2,pass2: SAS Device Slot Element: 1 Phys at Slot 2
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a2e
ses0: da3: Element descriptor: 'Slot 04'
ses0: da3: SAS Device Slot Element: 1 Phys at Slot 3
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a2f
ses0: da4: Element descriptor: 'Slot 05'
ses0: da4: SAS Device Slot Element: 1 Phys at Slot 4
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a30
ses0: da5: Element descriptor: 'Slot 06'
ses0: da5: SAS Device Slot Element: 1 Phys at Slot 5
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a31
ses0: da6: Element descriptor: 'Slot 07'
ses0: da6: SAS Device Slot Element: 1 Phys at Slot 6
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a32
ses0: da7: Element descriptor: 'Slot 08'
ses0: da7: SAS Device Slot Element: 1 Phys at Slot 7
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a33
ses0: da8: Element descriptor: 'Slot 09'
ses0: da8: SAS Device Slot Element: 1 Phys at Slot 8
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a34
ses0: da9: Element descriptor: 'Slot 10'
ses0: da9: SAS Device Slot Element: 1 Phys at Slot 9
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a35
ses0: da10: Element descriptor: 'Slot 11'
ses0: da10: SAS Device Slot Element: 1 Phys at Slot 10
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a36
ses0: da11: Element descriptor: 'Slot 12'
ses0: da11: SAS Device Slot Element: 1 Phys at Slot 11
ses0:  phy 0: SATA device
ses0:  phy 0: parent 5003048001a23a3f addr 5003048001a23a37
cd0 at ata0 bus 0 scbus1 target 1 lun 0
cd0: <MATSHITA DVD-ROM UJDA780 1.50> Removable CD-ROM SCSI device
cd0: 33.300MB/s transfers (UDMA2, ATAPI 12bytes, PIO 65534bytes)
cd0: Attempt to query device size failed: NOT READY, Medium not present - tray closed
SMP: AP CPU #1 Launched!
Timecounter "TSC-low" frequency 1330028520 Hz quality 1000
WARNING: WITNESS option enabled, expect reduced performance.
Trying to mount root from ufs:/dev/mfid0p2 [rw]...
ZFS filesystem version: 5
ZFS storage pool version: features support (5000)
uhub4: 8 ports with 8 removable, self powered
ugen2.2: <No brand> at usbus2
ukbd0: <No brand KVM, class 0/0, rev 1.10/0.00, addr 2> on usbus2
kbd2 at ukbd0
ugen4.2: <IntelR> at usbus4
umass0: <IntelR Multidevice, class 0/0, rev 2.00/0.01, addr 2> on usbus4
umass0:  SCSI over Bulk-Only; quirks = 0x0100
umass0:4:0: Attached to scbus4
umass1: <IntelR Multidevice, class 0/0, rev 2.00/0.01, addr 2> on usbus4
umass1:  SCSI over Bulk-Only; quirks = 0x0100
umass1:5:1: Attached to scbus5
umass2: <IntelR Multidevice, class 0/0, rev 2.00/0.01, addr 2> on usbus4
umass2:  SCSI over Bulk-Only; quirks = 0x0100
umass2:6:2: Attached to scbus6
umass3: <IntelR Multidevice, class 0/0, rev 2.00/0.01, addr 2> on usbus4
umass3:  SCSI over Bulk-Only; quirks = 0x0100
umass3:7:3: Attached to scbus7
ukbd1: <IntelR Multidevice, class 0/0, rev 2.00/0.01, addr 2> on usbus4
kbd3 at ukbd1
cd1 at umass-sim2 bus 2 scbus6 target 0 lun 0
cd1: <Intel(R) RMM2 VDrive 3 0.01> Removable CD-ROM SCSI-3 device
cd1: Serial Number 731284497BE433D913F08AD68B5E9D71
cd1: 40.000MB/s transfers
cd1: Attempt to query device size failed: NOT READY, Medium not present
cd1: quirks=0x10<10_BYTE_ONLY>
cd2 at umass-sim3 bus 3 scbus7 target 0 lun 0
cd2: <Intel(R) RMM2 VDrive 4 0.01> Removable CD-ROM SCSI-3 device
cd2: Serial Number 731284497BE433D913F08AD68B5E9D71
cd2: 40.000MB/s transfers
cd2: Attempt to query device size failed: NOT READY, Medium not present
cd2: quirks=0x10<10_BYTE_ONLY>
cd3 at umass-sim0 bus 0 scbus4 target 0 lun 0
cd3: <Intel(R) RMM2 VDrive 1 0.01> Removable CD-ROM SCSI-3 device
cd3: Serial Number 731284497BE433D913F08AD68B5E9D71
cd3: 40.000MB/s transfers
cd3: Attempt to query device size failed: NOT READY, Medium not present
cd3: quirks=0x10<10_BYTE_ONLY>
cd4 at umass-sim1 bus 1 scbus5 target 0 lun 0
cd4: <Intel(R) RMM2 VDrive 2 0.01> Removable CD-ROM SCSI-3 device
cd4: Serial Number 731284497BE433D913F08AD68B5E9D71
cd4: 40.000MB/s transfers
cd4: Attempt to query device size failed: NOT READY, Medium not present
cd4: quirks=0x10<10_BYTE_ONLY>
em0: link state changed to UP
uhid0: <IntelR Multidevice, class 0/0, rev 2.00/0.01, addr 2> on usbus4
ums0: <No brand KVM, class 0/0, rev 1.10/0.00, addr 2> on usbus2
ums0: 5 buttons and [XYZ] coordinates ID=1





-- 
Dave Robison
Senior Business Systems Analyst
FIS Banking Solutions
510/621-2089 (w)
530/518-5194 (c)
510/621-2020 (f)
daver_at_vicor.com
david.robison_at_fisglobal.com

_____________
The information contained in this message is proprietary and/or confidential. If you are not the intended recipient, please: (i) delete the message and all copies; (ii) do not disclose, distribute or use the message in any manner; and (iii) notify the sender immediately. In addition, please be aware that any message addressed to our domain is subject to archiving and review by persons other than the intended recipient. Thank you.
Received on Mon Mar 14 2016 - 21:16:09 UTC

This archive was generated by hypermail 2.4.0 : Wed May 19 2021 - 11:41:03 UTC