RE: SMART: disk problems on RAIDZ1 pool: (ada6:ahcich6:0:0:0): CAMstatus: ATA Status Error

From: Cy Schubert <Cy.Schubert_at_komquats.com>
Date: Tue, 12 Dec 2017 14:58:28 -0800
There are a couple of ways you can address this. You'll need to offline the vdev first. If you've done a smartcrl -t long and if the test failed, smartcrl -a will tell you which block it had an issue with. You can use dd, ddrescue or dd_rescue to dd the block over itself. The drive may rewrite the (weak) block or if it fails to it will remap it (subsequently showing as reallocated).

Of course there is a risk. If the sector is any of the boot blocks there is a good chance the server will hang.

You have to be *absolutely* sure which the bad sector is. And, there may be more. There is a risk of data loss.

I've used this technique many times. Most times it works perfectly. Other times the affected file is lost but the rest of the file system is recovered. And again there is always the risk.

Replace the disk immediately if you experience a growing succession of pending sectors. Otherwise replace the disk at your earliest convenience.

If using a zfs mirror (not in your case) detatch and attach will rewrite any weakly written sectors and reallocate pending sectors.

---
Sent using a tiny phone keyboard.
Apologies for any typos and autocorrect.
Also, this old phone only supports top post. Apologies.

Cy Schubert
<Cy.Schubert_at_cschubert.com> or <cy_at_freebsd.org>
The need of the many outweighs the greed of the few.
---

-----Original Message-----
From: O. Hartmann
Sent: 12/12/2017 14:19
To: Rodney W. Grimes
Cc: O. Hartmann; FreeBSD CURRENT; Freddie Cash; Alan Somers
Subject: Re: SMART: disk problems on RAIDZ1 pool: (ada6:ahcich6:0:0:0): CAMstatus: ATA Status Error

Am Tue, 12 Dec 2017 10:52:27 -0800 (PST)
"Rodney W. Grimes" <freebsd-rwg_at_pdx.rh.CN85.dnsmgr.net> schrieb:


Thank you for answering that fast!

> > Hello,
> > 
> > running CURRENT (recent r326769), I realised that smartmond sends out some console
> > messages when booting the box:
> > 
> > [...]
> > Dec 12 14:14:33 <3.2> box1 smartd[68426]: Device: /dev/ada6, 1 Currently unreadable
> > (pending) sectors Dec 12 14:14:33 <3.2> box1 smartd[68426]: Device: /dev/ada6, 1
> > Offline uncorrectable sectors
> > [...]
> > 
> > Checking the drive's SMART log with smartctl (it is one of four 3TB disk drives), I
> > gather these informations:
> > 
> > [... smartctl -x /dev/ada6 ...]
> > Error 42 [17] occurred at disk power-on lifetime: 25335 hours (1055 days + 15 hours)
> >   When the command that caused the error occurred, the device was active or idle.
> > 
> >   After command completion occurred, registers were:
> >   ER -- ST COUNT  LBA_48  LH LM LL DV DC
> >   -- -- -- == -- == == == -- -- -- -- --
> >   40 -- 51 00 00 00 00 c2 7a 72 98 40 00  Error: UNC at LBA = 0xc27a7298 = 3262804632
> > 
> >   Commands leading to the command that caused the error were:
> >   CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
> >   -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
> >   60 00 b0 00 88 00 00 c2 7a 73 20 40 08     23:38:12.195  READ FPDMA QUEUED
> >   60 00 b0 00 80 00 00 c2 7a 72 70 40 08     23:38:12.195  READ FPDMA QUEUED
> >   2f 00 00 00 01 00 00 00 00 00 10 40 08     23:38:12.195  READ LOG EXT
> >   60 00 b0 00 70 00 00 c2 7a 73 20 40 08     23:38:09.343  READ FPDMA QUEUED
> >   60 00 b0 00 68 00 00 c2 7a 72 70 40 08     23:38:09.343  READ FPDMA QUEUED
> > [...]
> > 
> > and
> > 
> > [...]
> > SMART Attributes Data Structure revision number: 16
> > Vendor Specific SMART Attributes with Thresholds:
> > ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
> >   1 Raw_Read_Error_Rate     POSR-K   200   200   051    -    64
> >   3 Spin_Up_Time            POS--K   178   170   021    -    6075
> >   4 Start_Stop_Count        -O--CK   098   098   000    -    2406
> >   5 Reallocated_Sector_Ct   PO--CK   200   200   140    -    0
> >   7 Seek_Error_Rate         -OSR-K   200   200   000    -    0
> >   9 Power_On_Hours          -O--CK   066   066   000    -    25339
> >  10 Spin_Retry_Count        -O--CK   100   100   000    -    0
> >  11 Calibration_Retry_Count -O--CK   100   100   000    -    0
> >  12 Power_Cycle_Count       -O--CK   098   098   000    -    2404
> > 192 Power-Off_Retract_Count -O--CK   200   200   000    -    154
> > 193 Load_Cycle_Count        -O--CK   001   001   000    -    2055746
> > 194 Temperature_Celsius     -O---K   122   109   000    -    28
> > 196 Reallocated_Event_Count -O--CK   200   200   000    -    0
> > 197 Current_Pending_Sector  -O--CK   200   200   000    -    1
> > 198 Offline_Uncorrectable   ----CK   200   200   000    -    1
> > 199 UDMA_CRC_Error_Count    -O--CK   200   200   000    -    0
> > 200 Multi_Zone_Error_Rate   ---R--   200   200   000    -    5
> >                             ||||||_ K auto-keep
> >                             |||||__ C event count
> >                             ||||___ R error rate
> >                             |||____ S speed/performance
> >                             ||_____ O updated online
> >                             |______ P prefailure warning
> > 
> > [...]  
> 
> The data up to this point informs us that you have 1 bad sector
> on a 3TB drive, that is actually an expected event given the data
> error rate on this stuff is such that your gona have these now
> and again.
> 
> Given you have 1 single event I would not suspect that this drive
> is dying, but it would be prudent to prepare for that possibility.

Hello.

Well, I copied simply "one single event" that has been logged so far.

As you (and I) can see, it is error #42. After I posted here, a reboot has taken place
because the "repair" process on the Pool suddenly increased time and now I'm with error
#47, but interestingly, it is a new block that is damaged, but the SMART attribute fields
show this for now:

[...]
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR-K   200   200   051    -    69
  3 Spin_Up_Time            POS--K   178   170   021    -    6075
  4 Start_Stop_Count        -O--CK   098   098   000    -    2406
  5 Reallocated_Sector_Ct   PO--CK   200   200   140    -    0
  7 Seek_Error_Rate         -OSR-K   200   200   000    -    0
  9 Power_On_Hours          -O--CK   066   066   000    -    25343
 10 Spin_Retry_Count        -O--CK   100   100   000    -    0
 11 Calibration_Retry_Count -O--CK   100   100   000    -    0
 12 Power_Cycle_Count       -O--CK   098   098   000    -    2404
192 Power-Off_Retract_Count -O--CK   200   200   000    -    154
193 Load_Cycle_Count        -O--CK   001   001   000    -    2055746
194 Temperature_Celsius     -O---K   122   109   000    -    28
196 Reallocated_Event_Count -O--CK   200   200   000    -    0
197 Current_Pending_Sector  -O--CK   200   200   000    -    0
198 Offline_Uncorrectable   ----CK   200   200   000    -    1
199 UDMA_CRC_Error_Count    -O--CK   200   200   000    -    0
200 Multi_Zone_Error_Rate   ---R--   200   200   000    -    5
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning
[...]


197 Current_Pending_Sector decreased to zero so far, but with every reboot, the error
count seems to increase:


[...]
Error 47 [22] occurred at disk power-on lifetime: 25343 hours (1055 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 c2 19 d9 88 40 00  Error: UNC at LBA = 0xc219d988 = 3256473992

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 b0 00 d0 00 00 c2 19 da 28 40 08  1d+07:12:34.336  READ FPDMA QUEUED
  60 00 b0 00 c8 00 00 c2 19 d9 78 40 08  1d+07:12:34.336  READ FPDMA QUEUED
  2f 00 00 00 01 00 00 00 00 00 10 40 08  1d+07:12:34.336  READ LOG EXT
  60 00 b0 00 b8 00 00 c2 19 da 28 40 08  1d+07:12:31.484  READ FPDMA QUEUED
  60 00 b0 00 b0 00 00 c2 19 d9 78 40 08  1d+07:12:31.483  READ FPDMA QUEUED


I think this is watching a HDD dying, isn't it?

I'd say, a broken cabling would produce different errors, wouldn't it?

The Western Digital Green series HDD is a useful fellow when the HDD is used as a single
drive. I think there might be an issue with paring 4 HDDs, 3 of them "GREEN", in a RAIDZ
and physically sitting next to each other. Maybe it is time to replace them one by one ...

> 
> 
> > 
> > The ZFS pool is RAIDZ1, comprised of 3 WD Green 3TB HDD and one WD RED 3 TB HDD. The
> > failure occured is on one of the WD Green 3 TB HDD.  
> Ok, so the data is redundantly protected.  This helps a lot.
> 
> > The pool is marked as "resilvered" - I do scrubbing on a regular basis and the
> > "resilvering" message has now aapeared the second time in row. Searching the net
> > recommend on SMART attribute 197 errors, in my case it is one, and in combination with
> > the problems occured that I should replace the disk.  
> 
> It is probably putting the RAIDZ in that state as the scrub is finding a block
> it can not read.
> 
> > 
> > Well, here comes the problem. The box is comprised from "electronical waste" made by
> > ASRock - it is a Socket 1150/IvyBridge board, which has its last Firmware/BIOS update
> > got in 2013 and since then UEFI booting FreeBSD from a HDD isn't possible (just to
> > indicate that I'm aware of having issues with crap, but that is some other issue
> > right now). The board's SATA connectors are all populated.
> > 
> > So: Due to the lack of adequate backup space I can only selectively backup portions,
> > most of the space is occupied by scientific modelling data, which I had worked on. So
> > backup exists! In one way or the other. My concern is how to replace the faulty HDD!
> > Most HowTo's indicate a replacement disk being prepared and then "replaced" via ZFS's
> > replace command. This isn't applicable here.
> > 
> > Question: is it possible to simply pull the faulty disk (implies I know exactly which
> > one to pull!) and then prepare and add the replacement HDD and let the system do its
> > job resilvering the pool?  
> 
> That may work, but I think I have a simpler solution.
> 
> > 
> > Next question is: I'm about to replace the 3 TB HDD with a more recent and modern 4 TB
> > HDD (WD RED 4TB). I'm aware of the fact that I can only use 3 TB as the other disks
> > are 3 TB, but I'd like to know whether FreeBSD's ZFS is capable of handling it?   
> 
> Someone else?
> 
> > 
> > This is the first time I have issues with ZFS and a faulty drive, so if some of my
> > questions sound naive, please forgive me.  
> 
> One thing to try is to see if we can get the drive to fix itself, first order
> of business is can you take this server out of service?  If so I would
> simply try to do a
> repeat 100 dd if=/dev/whicheverhdisbad of=/dev/null conv=noerror, sync iseek=3262804632
> 
> That is trying to read that block 100 times, if it successful even 1 time
> smart should remap the block and you are all done.

Given the fact, that this errorneous block is like a moving target, it this solution
still the favorite one? I'll try, but I already have the replacement 4 TB HDD at hand.

> 
> If that fails we can try to zero the block, there is a risk here, but raidz should just
> handle this as a data corruption of a block.  This could possibly lead to data loss,
> so USE AT YOUR OWN RISK ASSESMENT.
> dd if=/dev/zero of=/dev/whateverdrivehasissues bs=512 count=1 oseek=3262804632

I would then be  oseek=3256473992, too.

> 
> That should forceable overwrite the bad block with 0's, the smart firmware
> well see this in the pending list, write the data, read it back, if successful
> remove it from the pending list, if failed reallocate the block and write
> the 0's to the reallocation and add 1 to the remapped block count.
> 
> You might google for "how to fix a pending reallocation"
> 
> > Thanks in advance,
> > Oliver
> > -- 
> > O. Hartmann  
> 

Kind regards,

Oliver


-- 
O. Hartmann

Ich widerspreche der Nutzung oder Übermittlung meiner Daten für
Werbezwecke oder für die Markt- oder Meinungsforschung (§ 28 Abs. 4 BDSG).