Re: Mysterious 60min reboot on net4501

From: Harald Schmalzbauer <h_at_schmalzbauer.de>
Date: Wed, 17 Mar 2004 06:53:30 +0100
Am Mittwoch, 17. März 2004 00:35 schrieb Bernd Walter:
> On Tue, Mar 16, 2004 at 08:35:58PM +0100, Harald Schmalzbauer wrote:
> > Am Dienstag, 16. März 2004 20:29 schrieb Erik U.:
> > > Maybe something in the crontab that runs hourly and crashes your
> > > system.
> >
> > Cron doesn't run at all.
> >
> > If it only was that simple.....
>
> Maybe a too small power supply - current utilizes the CPU a bit more
> and therefor requires more power.
> At least -current never gave me such problems with soekris boards.

You are right, ther also was a problem with the power supply but I had 
replaced the old one by a 6V/2A model. I'm astonished about the 60 min 
interval. What bug could caus this? Today I'll revert all the "newies" like 
crypto hw/support aso.

Thanks,

-Harry

Received on Tue Mar 16 2004 - 20:53:42 UTC