Re: panic while playing with a ugen

From: Thierry Herbelot <thierry_at_herbelot.com>
Date: Sat, 3 Jun 2006 11:35:51 +0200
Le Thursday 1 June 2006 01:30, Anish Mistry a écrit :
> On Wednesday 31 May 2006 18:42, Thierry Herbelot wrote:
> > the panic occured when closing one endpoint of a ugen device (the
> > device was disconnecting from the USB bus after being reseted).
>
> I haven't seen this particular panic with ugen before.
> Try the patch in PR: usb/97271.  If you've got a test program and
> instructions that can reproduce this panic after applying that patch
> let me know.
>
> Thanks,

indeed, after applying the patch from usb/97271, the behaviour seems to be 
more stable (multiple runs of mytest program, in a loop, and not one panic so 
far).

	Thanks

	TfH
Received on Sat Jun 03 2006 - 07:36:20 UTC