Re: panic while playing with a ugen

From: Anish Mistry <mistry.7_at_osu.edu>
Date: Sat, 3 Jun 2006 17:31:06 -0400
On Saturday 03 June 2006 05:35, Thierry Herbelot wrote:
> Le Thursday 1 June 2006 01:30, Anish Mistry a écrit :
> > On Wednesday 31 May 2006 18:42, Thierry Herbelot wrote:
> > > the panic occured when closing one endpoint of a ugen device
> > > (the device was disconnecting from the USB bus after being
> > > reseted).
> >
> > I haven't seen this particular panic with ugen before.
> > Try the patch in PR: usb/97271.  If you've got a test program and
> > instructions that can reproduce this panic after applying that
> > patch let me know.
> >
> > Thanks,
>
> indeed, after applying the patch from usb/97271, the behaviour
> seems to be more stable (multiple runs of mytest program, in a
> loop, and not one panic so far).
Excellent.  I'm currently working with a commiter to get these changes 
into the tree.

-- 
Anish Mistry

Received on Sat Jun 03 2006 - 19:31:06 UTC