At 11:13 AM 8/7/2007, Dag-Erling Smørgrav wrote: >Mike Tancsa <mike_at_sentex.net> writes: > > But my other ich7 box works as expected (kldloads and box reboots > > after doing a kill -9 on watchdogd) > >with CURRENT or RELENG_6? RELENG_6 Original posted patch and your patch reboot this box running RELENG_6 ichwd0: <Intel ICH7 watchdog timer> at port 0x430-0x437,0x460-0x469 on isa0 ichwd0: Intel ICH7 watchdog timer (TCO version 2) ppc0: parallel port not found. ichwd module loaded ichwd0: <Intel ICH7 watchdog timer> on isa0 ichwd0: Intel ICH7 watchdog timer (ICH7 or equivalent) ppc0: parallel port not found. >I've tested the driver under -CURRENT on a couple more machines, with >the same result everywhere: it probes and attaches and seems to work >fine, but the box does not reboot. kldload ichwd, watchdogd -t 20;killall -9 watchdogd and nada ? I can boot one of my working RELENG_6 boxes on current and test if you think it is some version issue. ---Mike >I haven't tried RELENG_6 on the same hardware, though. > >I have no idea where to go on from here... >DES >-- >Dag-Erling Smørgrav - des_at_des.noReceived on Tue Aug 07 2007 - 13:29:57 UTC
This archive was generated by hypermail 2.4.0 : Wed May 19 2021 - 11:39:16 UTC