Hi, Using FreeBSD/amd64 7.0-BETA1 on a HP Proliant DL 380 G4 system, it freezes totally once the NIC is used, hanging at the time of setting the hostname upon boot. If I set hw.bge.allow_asf="0" in loader.conf, it works fine. What can I do to help debug this problem? About my NICs: bge0: <HP NC7782 Gigabit Server Adapter, ASIC rev. 0x2100> mem 0xfdef0000-0xfdef ffff irq 25 at device 1.0 on pci3 bge0: Reserved 0x10000 bytes for rid 0x10 type 3 at 0xfdef0000 miibus0: <MII bus> on bge0 brgphy0: <BCM5704 10/100/1000baseTX PHY> PHY 1 on miibus0 brgphy0: OUI 0x000818, model 0x0019, rev. 0 brgphy0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-F DX, auto bge0: bpf attached bge0: Ethernet address: 00:12:79:cf:57:33 ioapic1: routing intpin 1 (PCI IRQ 25) to vector 49 bge0: [MPSAFE] bge0: [ITHREAD] pci0:3:1:1: bad VPD cksum, remain 19 bge1: <HP NC7782 Gigabit Server Adapter, ASIC rev. 0x2100> mem 0xfdee0000-0xfdee ffff irq 26 at device 1.1 on pci3 bge1: Reserved 0x10000 bytes for rid 0x10 type 3 at 0xfdee0000 miibus1: <MII bus> on bge1 brgphy1: <BCM5704 10/100/1000baseTX PHY> PHY 1 on miibus1 brgphy1: OUI 0x000818, model 0x0019, rev. 0 brgphy1: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 1000baseT-F DX, auto bge1: bpf attached bge1: Ethernet address: 00:12:79:cf:57:32 ioapic1: routing intpin 2 (PCI IRQ 26) to vector 50 bge1: [MPSAFE] bge1: [ITHREAD] Only bge0 is being used. This seems to be the same problem described in PR kern/116328. Any takers? Bye, -- Anders.Received on Sun Oct 21 2007 - 12:48:45 UTC
This archive was generated by hypermail 2.4.0 : Wed May 19 2021 - 11:39:19 UTC