Re: HEADS UP: Major CAM performance regression

From: Andrea Venturoli <ml_at_netfence.it>
Date: Wed, 18 Feb 2009 12:51:12 +0100
Scott Long ha scritto:



Hello.



> The following configurations are known to be affected:
> 
> VMWare ESX
> VMWare Fusion
>     (using bt or lsilogic controller options)
> HP CISS RAID
> Some MPT-SAS combinations with SATA drives attached
>     (Includes Dell SAS5/ir, but not PERC5/PERC6).

Does it holds for any of these?
Or do you require a combination of factors?


I ask because I have two identical HP machines, one running 7.1p2/amd64, 
the other still at 7.1-PRERELEASE/amd64 and on both I get:
# camcontrol tags da0
(pass1:ciss0:0:0:0): device openings: 254

So it looks like I'm not affected, although I have a ciss RAID.


???


  bye & Thanks
	av.
Received on Wed Feb 18 2009 - 15:12:26 UTC

This archive was generated by hypermail 2.4.0 : Wed May 19 2021 - 11:39:42 UTC